Advanced Load Management Controlled Load Switch with Low RON
- Parameters
- Features
- Description
| Part number |
SY28481DCD |
| Vin (min) (V) |
0.5 |
| Vin (max) (V) |
13.5 |
| Vabs cont. (max) (V) |
18 |
| Iout (max) (A) |
24 |
| Protection mode |
OCP |
| Over current response |
Circuit breaker |
| Current limit (A) |
Adjustable |
| Fault response |
Latch-off |
| Ron (typ) (mΩ) |
4.1 |
| Certification recognition |
|
| Iq (typ) (uA) |
230 |
| Enable logic |
High |
| Soft start |
Adjustable |
| Features |
Output discharge |
| Package |
DFN3×3-12 |
| Operating temperature range(°C) |
-40 to 125 |
| Functional safety category |
|
- Advanced Controller with Charge Pump
- Integrated N-Channel MOSFET with Ultra Low RON
- Input Voltage Range 0.5 V to 13.5 V
- Soft-start via Controlled Slew Rate
- Adjustable Slew Rate Control
- Power Good Signal
- Thermal Shutdown
- Under Voltage Lockout
- Short Circuit Protection
- Extremely Low Standby Current
- Load Bleed (Quick Discharge)
- Pb-Free
The SY28481 load switch is an ultra-low on-resistance, compact device with inrush current limit via programmable soft−start. The device provides power good signaling for system status monitoring and downstream load control. With soft-start capability to reduce inrush current and low power consumption in a small footprint, the SY28481 is ideal for power management and hot-swap applications.
Under voltage lockout, short circuit protection and overternperature shutdown features are provided for reliable operation.
The SY28481 is available in a compact DFN33-12 package.
Evaluation Board
-
Photo of evaluation board
-
Photo of evaluation board
-
Photo of evaluation board
-
Photo of evaluation board
-
Photo of evaluation board
The EVB_SY28481DCD is intended for evaluating the advanced load management controlled Load Switch SY28481DCD.